Feature
Dimensions
|
mm |
|||
GA 160+-315 A/W |
3400 |
2000 |
2300 |
|
GA 160+-315 A - FF |
4300 |
2000 |
2300 |
|
GA 160+-315 W - FF |
3400 |
2000 |
2300 |
|
GA 160+-315 A/W (MV) |
3700 |
2000 |
2300 |
|
GA 160+-315 A - FF (MV) |
4600 |
2000 |
2300 |
|
GA 160+-315 W - FF (MV) |
3700 |
2000 |
2300 |
|
GA 200-315 VSDA |
3700 |
2000 |
2300 |
|
GA 200-315 VSDA - FF |
4600 |
2000 |
2300 |
|
GA 200-315 VSDW |
3700 |
2000 |
2300 |
|
GA 200-315 VSDW - FF |
3700 |
2000 |
2300 |
A = air-cooled. W = water-cooled. FF = Full Feature.
FAD (1) is measured at the following working pressures:
Standard |
||
5.5 bar version at |
5 bar | 5 bar |
7.5 bar version at |
7 bar |
7 bar |
8.5 bar version at |
8 bar |
8 bar |
10 bar version at |
9.5 bar |
9.5 bar |
14 bar version at |
13.5 bar |
12.5 bar |
Technical Specifications
TYPE |
Working pressure |
Capacity FAD (1) |
Installed motor power |
Noise level (2) |
Weight |
||||||||
Standard |
Full Feature (3) |
Standard / FullFeature |
Standard |
Full Feature |
|||||||||
bar(e) |
psig |
bar(e) |
psig |
l/s |
m³/min |
cfm |
kW |
dB(A) |
kg |
lb |
kg |
lb |
|
GA 160+ - 5.5 bar |
5.5 |
80 |
5.3 |
77 |
621 |
37.2 |
1316 |
160 |
77 |
3624 |
7990 |
4081 |
8997 |
GA 160+ - 7.5 bar |
7.5 |
109 |
7.3 |
106 |
538 |
32.2 |
1140 |
3624 |
7990 |
4081 |
8997 |
||
GA 160+ - 8.5 bar |
8.5 |
123 |
8.3 |
120 |
498 |
29.8 |
1055 |
3197 |
7049 |
3654 |
8057 |
||
GA 160+ - 10 bar |
10 |
145 |
9.8 |
142 |
448 |
26.9 |
949 |
3197 |
7049 |
3654 |
8057 |
||
GA 200 - 5.5 bar |
5.5 |
80 |
5.3 |
77 |
748 |
44.8 |
1585 |
200 |
78 |
3624 |
7990 |
4217 |
9297 |
GA 200 - 7.5 bar |
7.5 |
109 |
7.3 |
106 |
674 |
40.4 |
1428 |
4927 |
10862 |
5384 |
11870 |
||
GA 200 - 8.5 bar |
8.5 |
123 |
8.3 |
120 |
632 |
37.9 |
1339 |
4927 |
10862 |
5384 |
11870 |
||
GA 200 - 10 bar |
10 |
145 |
9.8 |
142 |
572 |
34.3 |
1212 |
4500 |
9922 |
4957 |
10929 |
||
GA 200 - 14 bar |
14 |
203 |
13.8 |
200 |
440 |
26.4 |
932 |
4500 |
9922 |
4957 |
10929 |
||
GA 250 - 7.5 bar |
7.5 |
109 |
7.3 |
106 |
833 |
49.9 |
1765 |
250 |
78 |
5144 |
11341 |
5737 |
12648 |
GA 250 - 8.5 bar |
8.5 |
123 |
8.3 |
120 |
773 |
46.3 |
1638 |
5144 |
11341 |
5601 |
12348 |
||
GA 250 - 10 bar |
10 |
145 |
9.8 |
142 |
709 |
42.5 |
1503 |
4717 |
10400 |
5174 |
11408 |
||
GA 250 - 14 bar |
14 |
203 |
13.8 |
200 |
575 |
34.5 |
1219 |
4717 |
10400 |
5174 |
11408 |
||
GA 315 - 7.5 bar |
7.5 |
109 |
7.3 |
106 |
1000 |
59.9 |
2119 |
315 |
78 |
5559 |
12256 |
6152 |
13563 |
GA 315 - 8.5 bar |
8.5 |
123 |
8.3 |
120 |
955 |
57.2 |
2024 |
5559 |
12256 |
6152 |
13563 |
||
GA 315 - 10 bar |
10 |
145 |
9.8 |
142 |
891 |
53.4 |
1888 |
5132 |
11315 |
5725 |
12622 |
||
GA 315 - 14 bar |
14 |
203 |
13.8 |
200 |
745 |
44.7 |
1579 |
5132 |
11315 |
5589 |
12323 |
TYPE |
|
Working pressure |
Capacity FAD (1) |
Installed motor power |
Noise level (2) |
Weight |
||||||||
Standard |
Full Feature (3) |
Standard / Full Feature |
Standard |
Full Feature |
||||||||||
bar(e) |
psig |
bar(e) |
psig |
l/s |
m³/min |
cfm |
kW |
dB(A) |
kg |
lb |
kg |
lb |
||
GA 200 VSD - |
Minimum |
5 |
72 |
5 |
72 |
211 - 806 |
12.7 - 48.4 |
447 - 1708 |
200 |
77 |
5682 |
12527 |
6221 |
13715 |
Nominal |
7 |
101 |
7 |
101 |
206 - 716 |
12.4 - 43.0 |
436 - 1517 |
|||||||
Maximum |
8.5 |
123 |
8.3 |
120 |
202 - 656 |
12.1 - 39.4 |
428 - 1390 |
|||||||
GA 200 VSD - |
Minimum |
6 |
87 |
6 |
87 |
100 - 611 |
6.0 - 36.7 |
212 - 1295 |
200 |
80 |
4352 |
9594 |
4891 |
10783 |
Nominal |
9.5 |
138 |
9.5 |
138 |
97 - 600 |
5.8 - 36.0 |
206 - 1271 |
|||||||
Maximum |
10 |
145 |
9.8 |
142 |
96 - 584 |
5.8 - 35.0 |
203 - 1237 |
|||||||
GA 200 VSD - |
Minimum |
9 |
131 |
9 |
131 |
98 - 608 |
5.9 - 36.5 |
208 - 1288 |
200 |
80 |
4352 |
9594 |
4891 |
10783 |
Nominal |
13.5 |
196 |
12.5 |
181 |
86 - 504 |
5.2 - 30.2 |
182 - 1068 |
|||||||
Maximum |
14 |
203 |
12.8 |
185 |
84 - 495 |
5.0 - 29.7 |
178 - 1049 |
|||||||
GA 250 VSD - |
Minimum |
5 |
72 |
5 |
72 |
211 - 900 |
12.7 - 54.0 |
447 - 1907 |
250 |
80 |
5682 |
12527 |
6301 |
13891 |
Nominal |
7 |
101 |
7 |
101 |
206 - 876 |
12.4 - 52.6 |
436 - 1856 |
|||||||
Maximum |
8.5 |
123 |
8.3 |
120 |
202 - 808 |
12.1 - 48.5 |
428 - 1712 |
|||||||
GA 250 VSD - |
Minimum |
6 |
87 |
6 |
87 |
208 - 899 |
12.5 - 53.9 |
441 - 1905 |
250 |
77 |
5255 |
11585 |
5874 |
12950 |
Nominal |
9.5 |
138 |
9.5 |
138 |
200 - 767 |
12.0 - 46.0 |
424 - 1625 |
|||||||
Maximum |
10 |
145 |
9.8 |
142 |
198 - 748 |
11.9 - 44.9 |
420 - 1585 |
|||||||
GA 315 VSD - |
Minimum |
5 |
72 |
5 |
72 |
211 - 1051 |
12.7 - 63.1 |
447 - 2237 |
315 |
79 |
5792 |
12769 |
6411 |
14134 |
Nominal |
7 |
101 |
7 |
101 |
206 - 1049 |
12.4 - 62.9 |
436 - 2223 |
|||||||
Maximum |
8.5 |
123 |
8,3 |
120 |
202 - 992 |
12.1 - 59.5 |
428 - 2102 |
|||||||
GA 315 VSD - |
Minimum |
6 |
87 |
6 |
87 |
208 - 1050 |
12.5 - 63.0 |
441 - 2225 |
315 |
80 |
5365 |
11828 |
5984 |
13192 |
Nominal |
9.5 |
138 |
9.5 |
138 |
200 - 947 |
12.0 - 56.8 |
424 - 2007 |
|||||||
Maximum |
10 |
145 |
9.8 |
142 |
198 - 925 |
11.9 - 55.5 |
420 - 1960 |
1. Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009). Reference conditions:
2. A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB). Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614. Pressure dew point of integrated refrigerant dryer at reference conditions: 2°C to 3°C (36°F to 37°F).
3. Integrated dryer: compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).