Technical specifications GA 15-26
50 Hz version
Compressor |
Pressure |
working |
Max. |
Capacity FAD* |
Installed |
Noise |
Weight |
||||||
Pack Floor |
FFTank |
||||||||||||
bar(e) |
psi |
l/s |
m3/min |
cfm |
kW |
hp |
dB(A) |
kg |
lbs |
kg |
lbs |
||
GA 15 |
7.5 |
7.5 |
109 |
45.8 |
2.75 |
97.1 |
15 |
20 |
65 |
421 |
928 |
474 |
1045 |
|
8.5 |
8.5 |
123 |
42.0 |
2.52 |
88.9 |
15 |
20 |
65 |
421 |
928 |
474 |
1045 |
|
10.5 |
10.5 |
152 |
38.8 |
2.33 |
82.2 |
15 |
20 |
65 |
421 |
928 |
472 |
1041 |
|
13 |
13.0 |
189 |
32.6 |
1.95 |
69.0 |
15 |
20 |
65 |
421 |
928 |
470 |
1036 |
GA 18 |
7.5 |
7.5 |
109 |
56.5 |
3.39 |
119.6 |
18.5 |
25 |
67 |
431 |
950 |
495 |
1091 |
|
8.5 |
8.5 |
123 |
53.8 |
3.23 |
114.0 |
18.5 |
25 |
67 |
431 |
950 |
495 |
1091 |
|
10.5 |
10.5 |
152 |
49.0 |
2.94 |
103.8 |
18.5 |
25 |
67 |
431 |
950 |
493 |
1087 |
|
13 |
13.0 |
189 |
40.7 |
2.44 |
86.2 |
18.5 |
25 |
67 |
431 |
950 |
491 |
1082 |
GA 22 |
7.5 |
7.5 |
109 |
65.1 |
3.91 |
138.0 |
22 |
30 |
68 |
440 |
970 |
495 |
1091 |
|
8.5 |
8.5 |
123 |
63.5 |
3.81 |
134.6 |
22 |
30 |
68 |
440 |
970 |
495 |
1091 |
|
10.5 |
10.5 |
152 |
53.3 |
3.20 |
112.9 |
22 |
30 |
68 |
440 |
970 |
493 |
1087 |
|
13 |
13.0 |
189 |
49.0 |
2.94 |
103.8 |
22 |
30 |
68 |
440 |
970 |
491 |
1082 |
GA 26 |
7.5 |
7.5 |
109 |
72.9 |
4.37 |
154.4 |
30 |
40 |
69 |
500 |
1102 |
558 |
1230 |
|
8.5 |
8.5 |
123 |
68.1 |
4.09 |
144.2 |
30 |
40 |
69 |
500 |
1102 |
558 |
1230 |
|
10.5 |
10.5 |
152 |
61.5 |
3.69 |
130.3 |
30 |
40 |
69 |
500 |
1102 |
556 |
1226 |
|
13 |
13.0 |
189 |
54.7 |
3.28 |
115.9 |
30 |
40 |
69 |
500 |
1102 |
554 |
1221 |
Latest Edition
Unit performance measured according to ISO 1217 ed. 4 2009, annex E, latest edition.
Mean noise level measuredat a distance of 1 m according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method); tolerance 3 dB(A).
. Intake air
. Air/oil mixture
. Oil
● Wet compressed air
. Condensate
● Dry air
● Gaseous coolant
● Liquid coolant
● Compressed air without free water
● Dry compressed air
● Water
● Refrigerant gas/liquid mixture
. High pressure, hot refrigerant gas
Low pressure, cool refrigerant gas
. High pressure refrigerant liquid
. Low pressure refrigerant liquid
60 Hz version
Compressor |
Pressure |
working |
Max. |
Capacity FAD* |
Installed |
Noise |
Weight |
||||||
Pack Floor |
FFTank |
||||||||||||
bar(e) |
psi |
l/s |
m3/min |
cfm |
kW |
hp |
dB(A) |
kg |
lbs |
kg |
lbs |
||
GA15 |
100 |
7.4 |
107 |
47.1 |
2.83 |
99.8 |
7.5 |
10 |
66 |
421 |
928 |
474 |
1045 |
|
125 |
9.1 |
132 |
42.4 |
2.54 |
89.8 |
7.5 |
10 |
66 |
421 |
928 |
474 |
1045 |
|
150 |
10.8 |
157 |
39.2 |
2.35 |
83.0 |
7.5 |
10 |
66 |
421 |
928 |
472 |
1041 |
|
175 |
12.5 |
181 |
30.3 |
1.82 |
64.2 |
7.5 |
10 |
66 |
421 |
928 |
470 |
1036 |
GA 18 |
100 |
7.4 |
107 |
56.9 |
3.41 |
120.5 |
11 |
15 |
68 |
431 |
950 |
495 |
1091 |
|
125 |
9.1 |
132 |
50.9 |
3.05 |
107.8 |
11 |
15 |
68 |
431 |
950 |
495 |
1091 |
|
150 |
10.8 |
157 |
48.0 |
2.88 |
101.7 |
11 |
15 |
68 |
431 |
950 |
493 |
1087 |
|
175 |
12.5 |
181 |
42.2 |
2.53 |
89.4 |
11 |
15 |
68 |
431 |
950 |
491 |
1082 |
GA22 |
100 |
7.4 |
107 |
67.7 |
4.06 |
143.3 |
15 |
20 |
69 |
440 |
970 |
495 |
1091 |
|
125 |
9.1 |
132 |
60.6 |
3.64 |
128.4 |
15 |
20 |
69 |
440 |
970 |
495 |
1091 |
|
150 |
10.8 |
157 |
54.4 |
3.26 |
115.2 |
15 |
20 |
69 |
440 |
970 |
493 |
1087 |
|
175 |
12.5 |
181 |
49.0 |
2.94 |
103.8 |
15 |
20 |
69 |
440 |
970 |
491 |
1082 |
GA 26 |
100 |
7.4 |
107 |
74.4 |
4.46 |
1576 |
18.5 |
25 |
70 |
500 |
1102 |
558 |
1230 |
|
125 |
9.1 |
132 |
69.5 |
4.17 |
147.2 |
18.5 |
25 |
70 |
500 |
1102 |
558 |
1230 |
|
150 |
10.8 |
157 |
62.8 |
3.77 |
133.0 |
18.5 |
25 |
70 |
500 |
1102 |
556 |
1226 |
|
175 |
12.5 |
181 |
57.1 |
3.43 |
120.9 |
18.5 |
25 |
70 |
500 |
1102 |
554 |
1221 |